Description
Altec AIR RHT 100 High Inlet Temperature Refrigerated Air Dryer
The Altec AIR RHT-0100-4 is part of the RHT Series High Inlet Temperature Refrigerated Air Dryers (10 to 120 SCFM) and is designed to be used with tank mounted piston-type air compressors that have no after-coolers.
The RHT Series is listed as not requiring separate after coolers, separators, or drains and is designed for high inlet temperature applications Up to 200°F. The series also lists consistent & reliable dry air (ISO Class 6), maximum pressure 232 PSIG, and ETL listed configurations (pending). This configuration includes a programmable timer installed (P).
Key Features
- Simplified installation: Does not require separate after coolers, separators, or drains.
- High inlet temperature: Up to 200°F.
- Dry air quality reference: Consistent & reliable dry air (ISO Class 6).
- Configuration listing: ETL listed configurations (pending).
- Maximum pressure: 232 PSIG.
- Electrical configuration: 460 VAC, 3 Phase, 60Hz.
- Programmable timer (P): Yes (Programmable Timer Installed).
Specifications
| Model | RHT-0100-4 |
|---|---|
| Dryer Type | High Inlet Temperature Refrigerated Air Dryer |
| Inlet Flow (Table Rating) | 100 SCFM @ 100 PSIG |
| Connection Size | 1-1/2" NPT |
| Operating Voltage | 460 VAC, 3 Phase, 60Hz |
| Maximum Pressure | 232 PSIG |
| High Inlet Temperature | Up to 200°F |
| Dry Air Quality Reference | ISO Class 6 |
| Sizing Basis (as listed) | Inlet Temperature 180°F; Inlet Dew Point of 160°F; Inlet Pressure of 175 PSIG; Outlet Dew Point of 50°F |
| Programmable Timer (P) | Yes (Programmable Timer Installed) |
Benefits
- Fewer components to add: Listed as not requiring separate after coolers, separators, or drains.
- Supports hot inlet air: High inlet temperature capability up to 200°F.
- Capacity matched by model: 100 SCFM inlet flow rating at 100 PSIG (table value).
- Power flexibility across the series: Multiple voltage/phase configurations are offered by model.
Installation & Application Notes
- Verify operating limits: Confirm inlet temperature and system pressure stay within listed limits (Up to 200°F; 232 PSIG).
- Use published sizing basis: The inlet flow ratings are shown as “SCFM @ 100 PSIG” with sizing based on: Inlet Temperature 180°F; Inlet Dew Point of 160°F; Inlet Pressure of 175 PSIG; Outlet Dew Point of 50°F.
- Corrected capacity method (variable conditions): Corrected Inlet Flow Capacity = INLET Flow (above) × Inlet Pressure Correction Factor (A) × Inlet Temp Correction Factor (B) × Ambient Temp Correction Factor (C).
- Correction factor tables: A: 100 PSIG (0.80), 125 PSIG (0.88), 150 PSIG (0.95), 175 PSIG (1.00), 200 PSIG (1.04). B: 100°F (3.31), 125°F (1.99), 150°F (1.30), 180°F (1.00), 200°F (0.91). C: 80°F (1.08), 90°F (1.06), 100°F (1.00), 110°F (0.90), 120°F (0.76).
The Altec AIR RHT-0100-4 is a fit for compressed air systems that need an RHT Series high inlet temperature refrigerated air dryer with 100 SCFM inlet flow rating at 100 PSIG, 1-1/2" NPT connections, and an electrical configuration of 460 VAC, 3 Phase, 60Hz.
Frequently Asked Questions
Altec AIR RHT-0100-4 High Inlet Temperature Refrigerated Air Dryer
▶️ Question: What compressor type is the RHT Series designed to be used with?
Answer: The price guide states the RHT Series is designed to be used with tank mounted piston-type air compressors that have no after-coolers.
▶️ Question: What is the listed high inlet temperature capability?
Answer: The RHT Series lists high inlet temperature capability up to 200°F.
▶️ Question: Does the RHT Series require separate after coolers, separators, or drains?
Answer: The price guide lists that the RHT Series does not require separate after coolers, separators, or drains.
▶️ Question: How do I size an RHT dryer when inlet conditions vary?
Answer: The price guide provides a corrected inlet flow capacity method: Corrected Inlet Flow Capacity = INLET Flow (SCFM @ 100 PSIG) × Correction Factor (A) × Correction Factor (B) × Correction Factor (C). It also provides correction factor tables for inlet pressure (A), inlet temperature (B), and ambient temperature (C).
▶️ Question: What does the “P” option indicate?
Answer: The model table defines “P” as a programmable timer installed. For RHT-0010-1, RHT-0015-1, and RHT-0020-1, the programmable timer is listed as not available. For other listed models, “-P” indicates the programmable timer installed configuration.