RHT-0100-4 460 VAC, 3 Phase, 60Hz High Inlet Temperature Refrigerated Air Dryer

blank star blank star blank star blank star blank star 0 reviews
  • Part Number: RHT-0100-4
  • Brand Altec
  • In/Out Connection 1 1/2" NPT
  • CFM Range 100-149 CFM
  • Air Dryer Type High Temp
  • Hertz 60 HZ
  • Max Inlet Temp. (F) 200
  • Max PSI 232 PSI
  • Phase 3 Phase
  • Voltage 460
  • Inlet Flow (scfm) 100
  • Cooling Air Cooled
  • Inlet Air Pressure (Operating) 175
  • Model RHT
  • Flow Rate (scfm) 100
View More Product Information

$8,244.00

Qty
Adding to cart… The item has been added

Estimated Lead Time

7-10 Days

Estimated Lead Time

7-10 Days

Product Resources

  • Part Number: RHT-0100-4
  • Brand Altec
  • In/Out Connection 1 1/2" NPT
  • CFM Range 100-149 CFM
  • Air Dryer Type High Temp
  • Hertz 60 HZ
  • Max Inlet Temp. (F) 200
  • Max PSI 232 PSI
  • Phase 3 Phase
  • Voltage 460
  • Inlet Flow (scfm) 100
  • Cooling Air Cooled
  • Inlet Air Pressure (Operating) 175
  • Model RHT
  • Flow Rate (scfm) 100
View More Product Information

Description

Altec AIR RHT 100 High Inlet Temperature Refrigerated Air Dryer

The Altec AIR RHT-0100-4 is part of the RHT Series High Inlet Temperature Refrigerated Air Dryers (10 to 120 SCFM) and is designed to be used with tank mounted piston-type air compressors that have no after-coolers.

The RHT Series is listed as not requiring separate after coolers, separators, or drains and is designed for high inlet temperature applications Up to 200°F. The series also lists consistent & reliable dry air (ISO Class 6), maximum pressure 232 PSIG, and ETL listed configurations (pending). A programmable timer installed is available on this model (P option).

Key Features

  • Simplified installation: Does not require separate after coolers, separators, or drains.
  • High inlet temperature: Up to 200°F.
  • Dry air quality reference: Consistent & reliable dry air (ISO Class 6).
  • Configuration listing: ETL listed configurations (pending).
  • Maximum pressure: 232 PSIG.
  • Electrical configuration: 460 VAC, 3 Phase, 60Hz.
  • Programmable timer (P): Not included (P option not selected).

Specifications

ModelRHT-0100-4
Dryer TypeHigh Inlet Temperature Refrigerated Air Dryer
Inlet Flow (Table Rating)100 SCFM @ 100 PSIG
Connection Size1-1/2" NPT
Operating Voltage460 VAC, 3 Phase, 60Hz
Maximum Pressure232 PSIG
High Inlet TemperatureUp to 200°F
Dry Air Quality ReferenceISO Class 6
Sizing Basis (as listed)Inlet Temperature 180°F; Inlet Dew Point of 160°F; Inlet Pressure of 175 PSIG; Outlet Dew Point of 50°F
Programmable Timer (P)Not included (P option not selected)

Benefits

  • Fewer components to add: Listed as not requiring separate after coolers, separators, or drains.
  • Supports hot inlet air: High inlet temperature capability up to 200°F.
  • Capacity matched by model: 100 SCFM inlet flow rating at 100 PSIG (table value).
  • Power flexibility across the series: Multiple voltage/phase configurations are offered by model.

Installation & Application Notes

  • Verify operating limits: Confirm inlet temperature and system pressure stay within listed limits (Up to 200°F; 232 PSIG).
  • Use published sizing basis: The inlet flow ratings are shown as “SCFM @ 100 PSIG” with sizing based on: Inlet Temperature 180°F; Inlet Dew Point of 160°F; Inlet Pressure of 175 PSIG; Outlet Dew Point of 50°F.
  • Corrected capacity method (variable conditions): Corrected Inlet Flow Capacity = INLET Flow (above) × Inlet Pressure Correction Factor (A) × Inlet Temp Correction Factor (B) × Ambient Temp Correction Factor (C).
  • Correction factor tables: A: 100 PSIG (0.80), 125 PSIG (0.88), 150 PSIG (0.95), 175 PSIG (1.00), 200 PSIG (1.04). B: 100°F (3.31), 125°F (1.99), 150°F (1.30), 180°F (1.00), 200°F (0.91). C: 80°F (1.08), 90°F (1.06), 100°F (1.00), 110°F (0.90), 120°F (0.76).

The Altec AIR RHT-0100-4 is a fit for compressed air systems that need an RHT Series high inlet temperature refrigerated air dryer with 100 SCFM inlet flow rating at 100 PSIG, 1-1/2" NPT connections, and an electrical configuration of 460 VAC, 3 Phase, 60Hz.

Frequently Asked Questions

Altec AIR RHT-0100-4 High Inlet Temperature Refrigerated Air Dryer

▶️ Question: What compressor type is the RHT Series designed to be used with?

Answer: The price guide states the RHT Series is designed to be used with tank mounted piston-type air compressors that have no after-coolers.

▶️ Question: What is the listed high inlet temperature capability?

Answer: The RHT Series lists high inlet temperature capability up to 200°F.

▶️ Question: Does the RHT Series require separate after coolers, separators, or drains?

Answer: The price guide lists that the RHT Series does not require separate after coolers, separators, or drains.

▶️ Question: How do I size an RHT dryer when inlet conditions vary?

Answer: The price guide provides a corrected inlet flow capacity method: Corrected Inlet Flow Capacity = INLET Flow (SCFM @ 100 PSIG) × Correction Factor (A) × Correction Factor (B) × Correction Factor (C). It also provides correction factor tables for inlet pressure (A), inlet temperature (B), and ambient temperature (C).

▶️ Question: What does the “P” option indicate?

Answer: The model table defines “P” as a programmable timer installed. For RHT-0010-1, RHT-0015-1, and RHT-0020-1, the programmable timer is listed as not available. For other listed models, “-P” indicates the programmable timer installed configuration.