Description
ZEKS HTB 15 HI-TEMP Refrigerated Air Dryer
The ZEKS HTB 15 is a HI-TEMP refrigerated compressed air dryer rated for applications with elevated inlet air temperatures. It is rated at 15 SCFM and is designed around listed operating conditions of 100 psig inlet pressure, 150°F inlet temperature, and 95°F ambient temperature.
For standard power and controls, the HTB 15 is supplied for 115 V / 60 Hz / 1 Phase service and includes a NEMA 12 electrical enclosure and an electronic drain as standard equipment. The maximum operating pressure is 200 psig, and the maximum inlet temperature is 200°F.
Key Features
- HI‑TEMP rated platform: built for elevated inlet air temperatures typical of tank‑mounted piston compressors.
- Moisture control: refrigerated drying to help reduce condensation in downstream piping and tools.
- Capacity: rated for 15 SCFM.
- Connections: 1/2".
- Pressure rating: up to 200 psig.
Specifications
| Model | HTB015A1D0 |
|---|---|
| Dryer Type | Refrigerated Air Dryer (ZEKS HI-TEMP™) |
| Rated Flow Capacity | 15 SCFM |
| Compressor (H.P.) | 1/6 HP |
| Max Operating Pressure | 200 psig |
| Connection Size | 1/2" |
| Operating Voltage | 115 V / 60 Hz / 1 Phase |
| Dimensions (in) | L 15 × D 20 × H 26 |
| Shipping Weight | 84 lb |
| Rating Basis | 100 psig inlet pressure / 150°F inlet temperature / 95°F ambient |
| Max Inlet Temperature | 200°F |
| Standard Equipment | NEMA 12; Electronic Drain |
| Recommended Prefilter (P/N) | ZFC22P |
| Optional Gauge Assembly (P/N) | 800872WCH (field installed) |
| Optional 3-Valve Bypass (P/N) | 800880WCH (field installed) |
| Internal Filter Element (Replacement P/N) | 684433 |
Benefits
- Protects downstream equipment: helps reduce moisture-related corrosion and contamination.
- Improves system reliability: supports consistent air quality for tools, controls, and processes.
- Handles hotter inlet air: supports applications where inlet temperatures are elevated.
- Right-sized capacity: 15 SCFM helps match system demand when applied at rating conditions.
Installation & Application Notes
- Ratings are based on 100 psig inlet pressure / 150°F inlet temperature / 95°F ambient.
- Verify system demand does not exceed 15 SCFM at the rating conditions.
- Keep operating pressure within the unit rating (up to 200 psig).
- Install the recommended prefilter ahead of the dryer to protect the refrigeration circuit and maintain air quality.
- Allow clearance for service access and condensate drain routing during installation.
ZEKS HTB 15 HI-TEMP Refrigerated Air Dryer is a strong fit when your system requirements match the listed capacity, pressure rating, and electrical configuration.
Frequently Asked Questions
ZEKS HTB 15 HI-TEMP Refrigerated Air Dryer
▶️ Question: What is the rated capacity for this model?
Answer: This model is rated for 15 SCFM under the series rating conditions.
▶️ Question: What does a refrigerated air dryer do?
Answer: It cools compressed air to condense water vapor, then removes the condensate to help reduce moisture in the air system.
▶️ Question: What are the connections and pressure rating?
Answer: It uses 1/2" connections and is rated up to 200 psig.
▶️ Question: What power does it require?
Answer: The unit configuration lists 115 V / 60 Hz / 1 Phase.
▶️ Question: What routine maintenance is typical?
Answer: Keep condenser surfaces clean, verify condensate drains operate correctly, and replace air filtration elements on schedule. It also lists footprint L 15 × D 20 × H 26.