Why Is My Air Compressor Overheating? Rotary Screw Air Compressor High Temp Issues Explained (With Fixes)
Posted by Industrial Air Centers on 09/29/2025
An overheating air compressor isn’t just inconvenient, it’s a serious issue that can damage components, reduce efficiency, and even lead to system failure if ignored. Rising temperature is a signal that something in the compression process (air intake, compression, cooling, or control) is off. Left alone, heat accelerates wear, trips safety devices, forces unplanned downtime, and drives up repair costs. This guide gives you a fast path to diagnose the root cause, implement the right fix, and prevent a repeat, whether you manage an industrial system running 24/7 or a small shop unit that supports a single line.
Signs Your Air Compressor is Overheating
High temperatures show up in several ways, some obvious, some more subtle:
- Automatic shutdowns or safety trips
- High temp alarms or warning lights
- Hot lubricant smell / burnt odor
- Excessive discharge temperature
If two of these appear together, plan an immediate inspection before restarting.
Common Causes of Rotary Screw Air Compressor Overheating
Most overheating problems can be traced back to a few root causes. Use these as your diagnostic short list:
Low or Poor-Quality Lubricant → Lack of Lubrication/Cooling
Lubricant both lubricates and carries heat away. Wrong grade, extended intervals, or low levels raise temps and accelerate wear.
Faulty Cooling System (Fans, Coolers, Blocked Vents)
Fouled coolers, failed fan motors, or obstructed louvers choke heat rejection. Clean fins, verify fan rotation/speed, and replace failed components.
Excessive Duty Cycle or Overloading
Running near 100% duty or feeding unexpected demand (leaks, unregulated end uses) pushes temperatures up. Demand control and smarter sequencing help.
High Ambient Temperature / Poor Ventilation
Compressors need cool, clean makeup air. Hot rooms, tight enclosures, or recirculating discharge air lead to heat soak. Cabinet intake filters can help keep debris out of enclosures, and room ventilation prevents heat buildup.
Malfunctioning Thermostats or Sensors
Failed thermostatic valves, bad RTDs/thermistors, or wiring faults can misread or mis-route temperature control, letting heat climb unchecked.
Varnish
Varnish build up in lubricant lines and coolers will restrict heat transfer and make rotary screw compressors run hot.
If you’re unsure which bucket you’re in, scan for the simplest problem first (clogged coolers, low lubricant level) before assuming component failure.
Immediate Steps to Take When a Compressor Overheats
If your compressor is running hot right now, here’s how to respond safely:
- Shut down immediately to prevent damage. Don’t try to “push through” a high-temp alarm.
- Allow a full cool-down before touching or opening panels. Follow your site’s LOTO and depressurization procedures.
- Check lubricant level and condition. If it’s low, milky, or smells burnt, plan a change with the correct grade.
- Inspect cabinet filtration and airflow. Replace clogged intake elements; clear debris from coolers and louvers.
- Verify room ventilation. Ensure exhaust air isn’t recirculating into the intake and that ambient temp is within spec.
- Restart cautiously only after you’ve corrected what you can see. Monitor discharge temperature and alarms closely.
Need parts fast?
→ Parts & Accessories (10,000+ SKUs)
Repair Solutions for Overheating Rotary Screw Compressors
Once you’ve diagnosed the cause, here are the most common fixes. Start with the highest-probability, lowest-risk actions; escalate if symptoms persist.
Replace Clogged Air Filters
Replace any clogged cabinet filters. if oil filter differential is high, change oil filter. If there is oil filter differential indicator check the time from last change and if it is close to being due or overdue then change the oil filter.
→ Filters / Regulators / Lubricators
Top Off or Replace the Compressor Lubricant
Use the correct grade/viscosity and change interval for your model and duty. If lubricant smells burnt or looks contaminated, perform a full change and filter replacement.
→ IAC Lubricants (engineered for compressor duty)
Clean or Repair Cooling Systems
Blow out coolers (opposite airflow), straighten fins, confirm fan operation and rotation, and replace failing components. Measure lubricant inlet and discharge temperature from cooler. it should be at least a 30F drop through the cooler for the compressor to run properly.
Fix or Replace Faulty Thermostats and Sensors
Check thermostatic valves, temperature probes, and wiring. Replace components that are out of spec or do not allow proper flow. (See our high temperature video for troubleshooting tips)
Check for Varnish
Remove the air/oil separator and check for excessive varnish. Some lubricants will degrade over time forming a thick varnish that will plug cooling passages in the compressor as well as form an insulating barrier in the coolers, not allowing proper heat transfer. if this is the case the machine will need to be flushed with a cleaner or changed to a lubricant with high detergent qualities and low probability to form more varnish.
Improve Location & Ventilation
If the room routinely exceeds recommended ambient temperature, add ventilation, duct discharge air away, or relocate the unit. In dusty environments, cabinet intake filtration helps protect enclosures.
Optional Engineered Controls for Stability
Master controller/sequencer to balance run hours and keep compressors in their optimal efficiency/temperature band.
Flow/pressure controller to decouple system pressure from demand spikes and reduce overworking compressors.
If temperatures remain high after these fixes, stop and escalate, persistent heat is a sign of deeper mechanical or control issues.
Preventing Future High Temperature Issues
Consistent maintenance is the best defense against overheating.
- Regular filter and lubricant changes to OEM schedule (and more often in harsh environments).
- Scheduled cooler cleaning (vacuum/air wash opposite normal flow; keep fins straight).
- Monitor discharge temperature trends in your logs; rising baseline temps are an early warning.
- Use auto-shutdowns and monitoring so high-temp events are caught before damage spreads (most units support alarm thresholds/logging).
- Keep compressor rooms ventilated and free of recirculated exhaust air; protect enclosures with cabinet intake filtration where dust is an issue.
For industrial plants, build these checks into your PM calendar and document readings (temperature, differential pressure, and amperage), so you can spot drift before it becomes downtime.
When to Call a Professional
Some overheating problems point to deeper issues that only trained technicians should handle:
- Recurring overheating despite filter/lubricant replacement
- Electrical issues tied to motor or controls (VFD trips, nuisance high-temp faults without clear cause)
- Airend damage or bearing failure signs (abnormal vibration/noise, metal in filters, rapid temp spikes)
- Industrial compressors with costly downtime (you need fast diagnosis, parts on-hand, and documentation)
IAC’s factory-trained technicians can verify temperatures, test sensors, clean/repair cooling systems, and get you back online quickly, with parts on the truck and access to 10,000+ products when replacements are needed.
→ Contact IAC here or call 877-IAC-SERV
Get Temps Down, Keep Production Up
An overheating rotary screw compressor is a warning sign you can’t afford to ignore, but with the right fixes and support, you can get back to full operation quickly.
Recap: Identify symptoms early → confirm the cause (filters, lubricant, cooling, load, ambient) → apply targeted fixes (replace elements, change lubricant, clean/repair coolers, correct duty/ventilation) → log and monitor to prevent a repeat
Quick Links
→ Shop Filters / Regulators / Lubricators
→ Shop Cooling System Products
Need expert support or facing an urgent overheating issue?
→ Contact IAC
Want to browse other categories?
→ Explore All IAC Products
Safety Note: Perform all work after proper lockout/tagout and full depressurization. Electrical and control diagnostics should be handled by qualified personnel.